DC Power Supply
| S.No | Parameter | Range/Characteristics | |
| 1 | Input | Voltage | Three phase 200 to 245 V |
| Current | 10 A | ||
| Frequency | 50 Hz | ||
| 2 | Output | Voltage | DC 285 to 350 V |
| Current | 7.3 A | ||
| 3 | LED indication | Power ON | |
| 4 | Operating position | Vertical | |
| 5 | Ambient temperature | 0 to 45 ℃ | |
Drive specifications
| S.No | Parameter | Range/Characteristics | |
| 1 | Input | Voltage | DC 285 to 350 V |
| Current | 0.26 A | ||
| 2 | Output | Voltage | Three phase 230 V |
| Current | 0.38 A | ||
| Power | 0.09 kW | ||
| 3 | Control method | Linear V/F | |
| 4 | Drive protection | Over voltage | |
| Under voltage | |||
| Over current | |||
| Over temperature | |||
| 5 | Analog inputs | 1 analog input 0-8 V for frequency command | |
| 6 | Digital inputs | 1 opto-isolated digital input for frequency command | |
| 7 | LED indication | Power ON | |
| Fault | |||
| 8 | Operating position | Vertical | |
| 9 | Ambient temperature | 0 to 45 ℃ | |
| 10 | Humidity | 90% with no condensation | |
BLDC drive specifications
| S.No | Parameter | Range/Characteristics | |
| 1 | Input | Voltage | DC 48V |
| Current | 3.3 A | ||
| 2 | Output Current | 2.8 A | |
| 3 | Drive protection | Over voltage | |
| Under voltage | |||
| Over current | |||
| Over temperature | |||
| Reverse polarity | |||
| 4 | Analog inputs | One analog input 0-10 V | |
| 5 | Digital inputs | Three opto-isolated digital inputs | |
| 6 | Hall switch inputs | Three pulse inputs | |
| 7 | LED indication | Power ON | |
| Fault | |||
| Enable | |||
| Communication | |||
| 8 | Fault relay output | 1 NO potential free contact; AC 250V, 10A | |
| 9 | Operating position | Vertical | |
| 10 | Ambient temperature | 0 to 45 ℃ | |
| 11 | Humidity | 90% with no condensation | |