0.09 kW drive specifications

S.No | Parameter | Range/Characteristics | |
1 | Input | Voltage | Single phase 90 to 265 V |
Current | 1.33 A | ||
Frequency | 50 Hz | ||
2 | Output | Voltage | Three phase 230 V |
Current | 0.5 A | ||
Power | 0.09 kW | ||
3 | Control method | Linear V/F | |
4 | Drive protection | Over voltage | |
Under voltage | |||
Over current | |||
Over temperature | |||
5 | Digital input | Two opto-isolated digital inputs: a) Enable b) Direction |
|
6 | LED indication | Power ON | |
Fault | |||
Forward | |||
Reverse | |||
7 | EMI filter | In-built | |
8 | Operating position | Vertical | |
9 | Ambient temperature | 0 to 45 ℃ | |
10 | Humidity | 90% with no condensation |
0.18 kW drive specifications

S.No | Parameter | Range/Characteristics | |
1 | Input | Voltage | Single phase 90 to 265 V |
Current | 3 A | ||
Frequency | 50 Hz | ||
2 | Output | Voltage | 230 V |
Current | 1.1 A | ||
Power | 0.18 kW | ||
3 | Control method | Linear V/F | |
4 | Drive protection | Over voltage | |
Under voltage | |||
Over current | |||
Over temperature | |||
5 | Communication port | One opto -isolated serial port | |
6 | LED indication | Power ON | |
Fault | |||
Forward | |||
Reverse | |||
7 | EMI filter | In-built | |
8 | Operating position | Vertical | |
9 | Ambient temperature | 0 to 45 ℃ | |
10 | Humidity | 90% with no condensation |
0.3 kW drive specifications

S.No | Parameter | Range/Characteristics | |
1 | Input | Voltage | Single phase 90 to 265 V |
Current | 4.2 A | ||
Frequency | 50 Hz | ||
2 | Output | Voltage | 230 V |
Current | 2.2 A | ||
Power | 0.30 kW | ||
3 | Control method | Linear V/F | |
4 | Drive protection | Over voltage | |
Under voltage | |||
Over current | |||
Over temperature | |||
5 | Analog inputs | One opto -isolated serial port | |
6 | Digital inputs | One opto-isolated digital input for direction | |
7 | LED indication | Power ON | |
Fault | |||
Forward | |||
Reverse | |||
8 | EMI filter | In-built | |
9 | Operating position | Vertical | |
10 | Ambient temperature | 0 to 45 ℃ | |
11 | Humidity | 90% with no condensation |